13S  30A/50A Lipo Battery BMS System

Discharge Current
Quantity

 

Security policy (edit with Customer reassurance module)

 

Delivery policy (edit with Customer reassurance module)

 

Return policy (edit with Customer reassurance module)

BMS - Battery management system for 13S Li_Ion Battery Cells  

Size: L110 * W50 * H12 mm (30A) ;  L125 * W60 * H12 mm (50A)

Specification:

Voltage Voltage 4.20±0.025V
Current Current - each cell 84±10mA
Static Current-each cell ≤20µA
Maximum Charge Current 5A
Maximum Continuous Discharge Current 30 / 50A
Charging Over Voltage Protection - each cell Charging Over Voltage Protection Detecting 4.250±0.025V
Charging Over Voltage Detecting Delay Time 0.5S-2S
Charging Over Voltage Protection Release 4.15±0.025V
Discharge Under Voltage Protection - each cell Discharge Under Voltage Protection Detecting 2.50±0.062V
Discharge Under Voltage Protection Delay Time 10mS - 200mS
Discharge Under Voltage Protection Release 2.9±0.1V
Over Current Protection Over Current Detection Voltage 0.62V/0.15±0.02V
Over Current Detection 100±10A/200±20A
Over Current Detection Delay Time 5mS - 60mS
Over Current Protection Release To disconnect load and recover automatically
Short Circuit Protection Short Circuit Protection Delay Time 200µs - 800µs
Short Circuit Protection Release To remove the short circuit and recover automatically
Impedance Protection Circuit(Mosfets) ≤20mΩ
Temperature Working Temperature -40°C - +85 °C
Storage Temperature -40°C - +125 °C