Lipo 3.6V 60AH LG Battery Cell
Capacity at RT Std. discharge Minimum 56.9Ah (Cmin)
Nominal voltage Average 3.6V
Standard charge Constant current 19.4A
Constant voltage 4.20V
End condition (Cut off) 2.9A
Temperature 25 ± 2ºC
Cycle charge Constant current 19.4A
(Refer to 4.1.2) Constant voltage 4.20V
End condition (Cut off) 2.9A
Temperature 25 ± 2ºC
Standard discharge Constant current 19.4A
(Refer to 4.1.3) End voltage (Cut off) 2.5V
Temperature 25 ± 2ºC
Cycle discharge Constant current 19.4A
(Refer to 4.1.4) End voltage (Cut off) 2.5V
Temperature 25 ± 2ºC
Safety charge Constant current 19.4A
(Refer to 4.1.5) Constant voltage 4.20V
End condition (Cut off) 2.9A
Temperature 25 ± 2ºC
Weight Approx. Max. 835g
Operating Charge1 0 ~ 45oC
Temperature Discharge2 -20 ~ 60oC
Max. Charge Constant current 19.4A
(0 ~ 45oC) Constant voltage 4.20V
End condition (Cut off) 2.9A
Max. Discharge Constant current 19.4A
(-20 ~ 60oC) End condition (Cut off) 2.5V
Storage Temperature 1 month -20 ~ 55oC
(for shipping state3) 3 month -20 ~ 45oC
1 year -20 ~ 25oC